Alert Fatigue
Described in Outpaced by AI by Waydell D. Carvalho.
- The Epic model fired on 18 percent of hospitalizations
- It missed 67 percent of sepsis cases
- Clinicians override drug alerts about 90 percent of the time
Outcome: Readers learn that detection without attention buys nothing.
In 2021, a team at Michigan Medicine tested the Epic Sepsis Model on 38,455 hospitalizations. The model fired on 18 percent of them. By the study's count, it missed 67 percent of the sepsis cases it was meant to catch.
The Epic model
Epic's electronic records hold the files of nearly 180 million people in the United States. Its Sepsis Model scored patients for sepsis, a fast and deadly reaction to infection. It came built in, and it was easy to switch on at no extra cost. Epic reported an area under the curve of 0.76 to 0.83.
Andrew Wong's team published the check in JAMA Internal Medicine. In the field, the number was 0.63. Positive predictive value was about 12 percent, so roughly 7 of every 8 alerts were for a patient without sepsis. Sensitivity was 33 percent. The alert came a median of just 2.5 hours before onset. Epic disputed the study, and part of the gap came from how sepsis timing was defined. The 18 percent alert rate does not depend on that definition.
The model missed 1,709 sepsis patients. Of those, 1,030 still got timely antibiotics through ordinary care. The ward caught what the model did not.
The wider pattern
Studies found override rates of 49 to 96 percent for safety alerts. A 2024 review pooled the override rate for drug interaction alerts at 90 percent. Jessica Ancker found that once a clinician overrode an alert, the chance of overriding the next one was 99.9 percent.
At Penn Medicine, a team surveyed staff about a second sepsis model. Only about 13 percent of providers and about 24 percent of nurses said the alerts gave a new clinical finding.
The same idea can work. The TREWS system reached clinicians who evaluated 89 percent of its alerts. Where a provider confirmed an alert within 3 hours, the adjusted risk of death was 18.7 percent lower. It sent each alert to a clinician who owned it.
The naming
Any detector can be tuned to catch more. Past a point, it fires on almost everything. A missed sepsis death is a disaster and a false alarm is an interruption, so designers turn the dial up. AI can score every patient all the time, so the flood grows.
The fix is not better paperwork. The configuring, the committee, and the dashboard do not create attention. The test is simple. If staff still act on true alerts as volume climbs, the diagnosis is wrong.